43. BACKUP Backup parameters and save them in the EEPROM memory module.
All of the conguration setting parameters can be saved in the EEPROM memory
module for backup. The backup parameters can then be restored if they have been
inadvertently changed or corrupted. Once backup is complete the EEPROM memory
module may be removed for safe storage. All EDI-120 retrot control systems are
shipped with the factory default settings saved in the EEPROM memory module.
Press EXECUTE to enter the menu.
DISABLED This menu is disabled to help prevent inadvertent changes. Proceed to enable.
ENABLED Press and hold MENU ( ) and MENU ( ) at the same time for 4-5 seconds.
MEMCHECK Automatically checks the EEPROM memory module for parameter type.
SURE ??? Press EXECUTE to proceed.
WAIT Automatically begins parameter backup and generates CRC value.
VERIFY Automatically veries parameter backup data and CRC value.
DONE!! Parameter backup is done and saved in the EEPROM memory module.
NO MEM! Displayed if an EEPROM memory module is not detected.
WRONG Displayed if the wrong type (parameter) of EEPROM memory module detected.
MEM TYPE Displayed if the wrong type (parameter) of EEPROM memory module detected.
WRONG Displayed if the wrong product type of EEPROM memory module detected.
PRODUCT Displayed if the wrong product type of EEPROM memory module detected.
DATA ERR Displayed when a data error occurs. Waits for key press to restart BACKUP..
NOTE: Be sure to BACKUP the EDI-120 when installation conguration is complete.
44. PRINTOUT Print various system conguration settings using a hand held infrared printer.
All EDI-120 retrot control systems come equipped with an infrared (I/R) LED that
provides the ability to printout all the system conguration settings, when used in
conjunction with a hand held infrared printer (
Johnson System Inc., Part Number: JS-IP
).
Point the hand held printer I/R LED directly at the EDI-120 retrot control system
PRINTER I/R LED within 3 ft (1m).
Press EXECUTE to enter the menu.
Press MENU ( ) to scroll through and select which item(s) to printout.
SYSTEM? Prints general system information and conguration settings.
ANALOGS? Prints the channel patch for all 4 analog inputs.
Ø-PATCH? Prints the phase patch for all 120 dimmer outputs.
CURVES? Prints the dimmer curves for all 120 dimmer outputs.
F-ALARM? Prints the conguration settings for the re alarm input.
S-ALARM? Prints the conguration settings for the security alarm input.
SCENE? Prints the level settings for each of the 120 dimmers within the 12 scenes.
SCENE>01 Press EXECUTE to toggle the pointer (>) and select which scene to print.
SCENE>FL Press MENU ( ) to select the desired scene (01 to 12) or all scenes (FL).
V-LIMIT? Prints the output voltage limit settings for each of the 120 dimmer outputs.
DCPATCH? Prints the conguration settings for the dimmer to channel patch.
FD-TIME? Prints the fade time settings for each of the 12 scenes.
2 ROOM? Prints the two room assignment for each of the 120 dimmer outputs.
DMXAPAT? Prints the DMX A patch for each of the 120 dimmer outputs.
DMXBPAT? Prints the DMX B patch for each of the 120 dimmer outputs.
ALL? Printout all items at once.
PRINTING Press EXECUTE on any item to begin printing.