User Manual
DPC-12 & DPC-24
3000 Series Digital Pack Controller
Control Retrofit for CD80 Portable Dimmer Packs
Model Description
DPC-12 CD80 12 x 2.4kW, 6 x 6kW and 6 x 12kW Portable Dimmer Packs.
DPC-24 CD80 24 x 1.2 kW and 24 x 2.4kW Portable Dimmer Packs
CD80 48 x 2.4kW Compact Rolling Racks (requires 2 per rack).
JOHNSON SYSTEMS INC.
www.johnsonsystems.com
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - DPC-12 & DPC-24

User ManualDPC-12 & DPC-243000 Series Digital Pack ControllerControl Retrofit for CD80 Portable Dimmer PacksModel DescriptionDPC-12 CD80 12 x 2.4kW

Pagina 2 - Table of Contents

www.johnsonsystems.com10 XXX XXXSame as above except the “A” and “B” is replaced with “ ” to indicate if one or both of the DMX inputs are te

Pagina 3 - Introduction

www.johnsonsystems.com 11Quick Programming Reference to System Configuration Menu ItemsBasic Menus1. ADDRESS Set the DMX start address.2. DMXA-TRM

Pagina 4 - DPC-24/12

www.johnsonsystems.com12Detailed Programming of System Configuration Menu ItemsNOTE: When the DPC-12 or DPC-24 is powered up, the menus are “LOCKED!!”

Pagina 5 - DPC-24/12 Circuit Board

www.johnsonsystems.com 13Advanced Menus4. SCENESET Enable and setup 12 or 24 different backup scenes. When scene mode (SCENESET) is activated the

Pagina 6

www.johnsonsystems.com146. SNAPSHOT Record DMX levels into the backup scenes. Provides a quick and easy way to save control channel levels into ea

Pagina 7 - User Interface

www.johnsonsystems.com 15 PTY A Press EXECUTE to toggle into Priority A (PTY A) mode. PTY B Press EXECUTE to toggle into Priority B (PTY B) mode.

Pagina 8 - Programming Switches

www.johnsonsystems.com16 D24<C01 Press EXECUTE to toggle the pointer (<) to select another dimmer output. Press ESCAPE to exit the menu an

Pagina 9 - System Status - LCD Display

www.johnsonsystems.com 1717. TEST INC Set the test increment units to percent or hexadecimal. The level for the dimmer test (DIM TEST) menu can b

Pagina 10

www.johnsonsystems.com1820. V-RANGE Set the supply voltage range for 120 Volts or 240 Volts operation. DPC-12 and DPC-24 retrot control modules a

Pagina 11

www.johnsonsystems.com 19 K:XXX>XX Press MENU ( ) to modify the fth hard-key character. K:XXXX>X Press EXECUTE to advance to the sixt

Pagina 12 - channels

www.johnsonsystems.com2WarrantyDPC-12 and DPC-24 retrot control modules comes with a standard one (1) year limited warranty against defects in parts

Pagina 13 - Advanced Menus

www.johnsonsystems.com20 WILL Firmware update in progress. AUTO Firmware update in progress. RESTART Firmware update in progress. PLEASE Fi

Pagina 14 - channels programmed via the

www.johnsonsystems.com 2131. BACKUP Backup parameters and save them in the EEPROM memory module. All of the conguration setting parameters can be

Pagina 15

www.johnsonsystems.com2233. DEFAULTS Set various system conguration settings to the factory default. Press EXECUTE to enter the menu. Press M

Pagina 16

www.johnsonsystems.com 23JSI Serial Number: ___________________Silicone Serial Number: _______________Hard-Key Code: _____________________JSI Seria

Pagina 17

www.johnsonsystems.comUser ManualDPC-12 & DPC-243000 Series Digital Pack ControllerControl Retrot for CD80 Portable Dimmer PacksRev. 1

Pagina 18

www.johnsonsystems.com 3IntroductionDigital Pack Controllers (DPC’s) are a next generation retrot electronics package designed specically for upgrad

Pagina 19

www.johnsonsystems.com4EEPROMMEMORYMODULEEEPROMBACKUP &FIRMWAREUPDATE(EDGE3) (EDGE2)MOVE JUMPERS (x3)TO LEFT-HAND SIDE POSITIONTO ENABLE INTERNA

Pagina 20

www.johnsonsystems.com 5EEPROMMEMORYMODULEEEPROMBACKUP &FIRMWAREUPDATE(EDGE3) (EDGE2)MOVE JUMPERS (x3)TO LEFT-HAND SIDE POSITIONTO ENABLE INTERN

Pagina 21

www.johnsonsystems.com6Dual DMX Input and Thru Connectors (5-Pin XLR)System Status - LED IndicatorsLCD DisplayProgramming SwitchesLocal Button/Switche

Pagina 22

www.johnsonsystems.com 7DMX Input and Thru5-Pin XLR ConnectorsPIN FUNCTION1 DMX Shield / Common2 DMX Data-3 DMX Data+4 Pass Thru Connection5 Pass Thru

Pagina 23 - Troubleshooting Reference

www.johnsonsystems.com8LCD DisplayThe LCD display is capable of displaying 2 lines of 8 characters. A backlight automatically comes on when activity i

Pagina 24 - User Manual

www.johnsonsystems.com 9System Status - LED IndicatorsRUN (Green)Illuminates when the power is on and the microcontroller status is in normal run mode