Johnson-systems CD-3000 Series Retrofit Control System Manual de usuario

Busca en linea o descarga Manual de usuario para Encendiendo Johnson-systems CD-3000 Series Retrofit Control System. Johnson Systems CD-3000 Series Retrofit Control System User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 38
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
R
E
C
Y
C
L
E
R
E
U
S
E
R
E
T
R
O
F
I
T
!
User Manual
CD-3000 Series
Retrofit Control System
JOHNSON SYSTEMS INC.
www.johnsonsystems.com
2002161
Model Application
CD-3000-AE Strand CD80
®
AMX or Advanced Electronic (AE) permanent installation racks.
CD-3000-AE-48RR Strand CD80
®
AMX or Advanced Electronic (AE) 48 channel rolling racks
CD-3000-AE-96RR Strand CD80
®
AMX or Advanced Electronic (AE) 96 channel rolling racks
CD-3000-SV Strand CD80
®
Supervisor (SV) permanent installation racks
CD-3000-SV-48RR Strand CD80
®
Supervisor (SV) 48 channel rolling racks
CD-3000-SV-96RR Strand CD80
®
Supervisor (SV) 96 channel rolling racks
CD-3000-C21 Strand C21 permanent installation racks
Vista de pagina 0
1 2 3 4 5 6 ... 37 38

Indice de contenidos

Pagina 1 - User Manual

RECYCLE REUSE RETROFIT!User ManualCD-3000 SeriesRetrofit Control SystemJOHNSON SYSTEMS INC.www.johnsonsystems.com2002161Model ApplicationCD-3000-AE

Pagina 2 - Contents

www.johnsonsystems.com10CD-3000-AE Dimmer Control Cable PinoutJ1AE Connector J2AE Connector J3AE Connector J4AE ConnectorPIN FUNCTION PIN FUNCTION PIN

Pagina 3 - Introduction

www.johnsonsystems.com 11CD-3000-SV Dimmer Control Cable Pinout#1 Top Columns #2 Top Columns #3 Top ColumnsPIN FUNCTION PIN FUNCTION PIN FUNCTION1 Dim

Pagina 4 - CD-3000-AE

www.johnsonsystems.com121 J3AE J1AE J2AE J4AE J1SV J10SV J11SV J12SV J2SV J3SV J4SV J5SV J6SV J7SV J8SV J9SV J17 J18 J7 J8 J16 J15 J12 J11 J10 J9 J4

Pagina 5

www.johnsonsystems.com 13+12V+12VCommonAnalogInput1 Thru 4Common+12VAnalogInput1 Thru 4MaintainedNormallyOpenSwitchContactControl Input/Output Connect

Pagina 6 - CD-3000-AE-96RR

www.johnsonsystems.com14+12VOvertempInputNormallyClosedNormallyClosedThermostatSwitchNormallyOpenThermostatSwitchOvertempInputNormallyOpenCommonMainta

Pagina 7 - CD-3000-SV

www.johnsonsystems.com 15D294 D295 D296 D212 D211 D210 D209 D208 D207 D206 D205 D204 D203 D202 D201 R202 R204 R206 R208 R210 R212 R214 R216 R218 R220

Pagina 8

www.johnsonsystems.com16User InterfaceAll CD-3000 Series retrot systems are equipped with a user interface. The user interface provides access t

Pagina 9 - CD-3000-C21

www.johnsonsystems.com 17System Status • LED IndicatorsRUN (Green)Illuminates when the power is on and the microcontroller status is in normal run mod

Pagina 10

www.johnsonsystems.com18INF HOLDDisplayed when DMX is disconnected and the systems predetermined DMX status hold (SH) time is set for innite (INF) ho

Pagina 11

www.johnsonsystems.com 19Quick Programming Reference to System Configuration Menu Items1. SCENESET Enable and setup 20 different backup scenes.2. FADE

Pagina 12 - CD-3000

www.johnsonsystems.com2RECYCLE REUSE RETROFIT!WarrantyThe CD-3000 comes with a standard one (1) year limited warranty. Extended warranties of up t

Pagina 13

www.johnsonsystems.com20Detailed Programming of System Configuration Menu ItemsNOTE: The programming switches can be locked out to prevent inadvertent

Pagina 14

www.johnsonsystems.com 213. SNAPSHOT Record DMX levels into the backup scenes. Provides a quick and easy way to save control channel levels into e

Pagina 15 - Control Module • MADD-96

www.johnsonsystems.com227. DMX MODE Congure the mode of the on-board DMX protocol manager. There are ve different mode settings for the DMX pro

Pagina 16 - User Interface

www.johnsonsystems.com 239. DMXA TRM Enable or disable termination on the DMX A input. Activates and deactivates a 120Ω termination resistor. DMX

Pagina 17 - System Status • LCD Display

www.johnsonsystems.com24 For a more complex example, if DIM# is 049, DMX is 321, and #DIM is 024, then dimmer outputs 049 thru 073 are addressed sequ

Pagina 18

www.johnsonsystems.com 2513. DMXB PAT Patch the 96 dimmer (PWM) outputs to any DMX B input channel. Refer to the DMXA PAT menu for further infor

Pagina 19

www.johnsonsystems.com2617. VOUT LIM Set the maximum RMS output voltage for each dimmer. Limiting the maximum RMS voltage can greatly improve lam

Pagina 20

www.johnsonsystems.com 2721. ANA TEST View the control level for each of the analog inputs. The analog voltage level for the 4 analog inputs can

Pagina 21 - channels

www.johnsonsystems.com2826. OC MODE Congure the input trigger parameters for the open collector output. The on-board open collector output is u

Pagina 22 - channels programmed via the

www.johnsonsystems.com 2930. F-ALARM Select the level and control channels triggered by the re alarm input. When a contact is sensed on the re a

Pagina 23

www.johnsonsystems.com 3IntroductionThe JSI CD-3000 is a next generation retrot electronics package designed specically for any vintage of Strand CD

Pagina 24

www.johnsonsystems.com3033. POLARITY Set the PWM output control polarity. Locked for factory use only! This menu is only used when swapping contro

Pagina 25

www.johnsonsystems.com 31 K>XXXXXX A pointer (>) appears to indicate hard-key modication is activated. K>XXXXXX Press MENU ( ) to

Pagina 26

www.johnsonsystems.com32 CRC-TEST Automatically does a CRC test on the rmware code in the EEPROM. >>>>>>>> The CRC test i

Pagina 27

www.johnsonsystems.com 3345. BACKUP Backup parameters and save them in the EEPROM memory module. All of the conguration setting parameters can be

Pagina 28

www.johnsonsystems.com3447. DEFAULTS Set various system conguration settings to the factory default. Press EXECUTE to enter the menu. Press

Pagina 29

www.johnsonsystems.com 35JSI Serial Number: ___________________Silicone Serial Number: _______________Hard-Key Code: _____________________JSI Seria

Pagina 30

www.johnsonsystems.com36Troubleshooting ReferenceThis manual is accurate at time of printing and subjectto revisions and technical updates as required

Pagina 31

www.johnsonsystems.com 37Troubleshooting ReferenceThis manual is accurate at time of printing and subjectto revisions and technical updates as require

Pagina 32

www.johnsonsystems.comRECYCLE REUSE RETROFIT!User ManualCD-3000 Series Retrot Control SystemRev. 4

Pagina 33

www.johnsonsystems.com4Packaging & ContentsEach CD-3000 Series retrot system is shipped in a custom designed box for protection of the unit. Keep

Pagina 34

www.johnsonsystems.com 5• Unscrew the two mounting (thumb) screws that hold the old processor housing in place. Slowly remove the old card cage, taki

Pagina 35

www.johnsonsystems.com6• Remove the protective foam caps.• Place the CD-3000-AE onto the CD-80® dimmer rack guide rails located on each side an

Pagina 36 - Troubleshooting Reference

www.johnsonsystems.com 7• Remove the old fan housing similarly to the processor housing and set aside.• Place the fan housing assembly in front of t

Pagina 37

www.johnsonsystems.com8• Note the location and function of all control cables landed on the circuit board on top of the processor housing. Label cabl

Pagina 38

www.johnsonsystems.com 9• Connect all other applicable low voltage control input/output connections to the backplane.• Connect the power connector (