Pagina 2 - Contents

WWW.JOHNSONSYSTEMS.COM10Output Connector/Receptacle OptionsJ-PACK Series dimmer packs are designed for high performance dimming of standard incandesce

Pagina 3 - Introduction

WWW.JOHNSONSYSTEMS.COM 11Terminal Block Connection DetailsNOTE: This option is intended for permanent installation application only.Remove the top pa

Pagina 4 - Characteristics

WWW.JOHNSONSYSTEMS.COM12 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6Control Inp

Pagina 5 - Top View

WWW.JOHNSONSYSTEMS.COM 13WWW.JOHNSONSYSTEMS.COMMAAD-6REV.11240MADE IN CANADASERIAL NUMBERWARNING: AC LINE VOLTAGEMAAD-6REV.112405-Pin XLR Connection D

Pagina 6 - Mounting Options

WWW.JOHNSONSYSTEMS.COM14EXECUTE ESCAPE RESETRUN ØA ØB ØC RxD ERRORMENUUser InterfaceAll J-PACK Series dimmer packs ar

Pagina 7

WWW.JOHNSONSYSTEMS.COM 15System Status • LED Indicators RUN (Green)Illuminates when the power is on and the microcontroller status is in normal run mo

Pagina 8 - AC Power Supply Input Options

WWW.JOHNSONSYSTEMS.COM16INF HOLD Displayed when DMX is disconnected and the systems predetermined DMX status hold (SH) time is set for innite (INF) h

Pagina 9

WWW.JOHNSONSYSTEMS.COM 17Quick Programming Reference to System Configuration Menu ItemsBasic Menus1. ADDRESS Set the DMX start address.2. DMX TERM

Pagina 10

WWW.JOHNSONSYSTEMS.COM18Detailed Programming of System Configuration Menu ItemsNOTE: When the J-PACK Series dimmer pack is powered up, the menus are “

Pagina 11

WWW.JOHNSONSYSTEMS.COM 19Advanced Menus3. SCENESET Enable and setup 6 different backup scenes. When scene mode (SCENESET) is activated the select

Pagina 12 - Control Input

WWW.JOHNSONSYSTEMS.COM2WarrantyJ-PACK Series dimmer packs come with a standard one (1) year limited warranty. Extended warranties of up to ten (10) ye

Pagina 13 - MADE IN CANADA

WWW.JOHNSONSYSTEMS.COM205. SNAPSHOT Record DMX levels into the backup scenes. Provides a quick and easy way to save control channel levels into e

Pagina 14 - User Interface

WWW.JOHNSONSYSTEMS.COM 219. DMX PAT Patch the 6 dimmer (PWM) outputs to any DMX input channel. Full exibility is provided to manually patch any

Pagina 15 - System Status • LCD Display

WWW.JOHNSONSYSTEMS.COM2212. DIM CURV Congure the dimmer curve for each output. There are four different dimmer curve proles that can be assigne

Pagina 16

WWW.JOHNSONSYSTEMS.COM 2316. TEST INC Set the test increment units to percent or hexadecimal. The level for the dimmer test (DIM TEST) menu can b

Pagina 17 - WWW.JOHNSONSYSTEMS.COM 17

WWW.JOHNSONSYSTEMS.COM2420. AUX2MODE Set the auxiliary input 2 mode to activate a selected scene or load shed. The auxiliary dry-contact input ca

Pagina 18

WWW.JOHNSONSYSTEMS.COM 2522. Ø-PATCH Set the zero-cross phase reference for each dimmer control output circuit. The defaults (DEFAULTS) menu is n

Pagina 19 - Advanced Menus

WWW.JOHNSONSYSTEMS.COM2625. LINE V View the RMS line voltage for each power phase. Press EXECUTE to enter the menu and view the line voltage of e

Pagina 20

WWW.JOHNSONSYSTEMS.COM 2731. SERIAL# View the microcontroller’s unique eight-character silicone serial number. XXXXXXXX Shows the unique eight-cha

Pagina 21 - WWW.JOHNSONSYSTEMS.COM 21

WWW.JOHNSONSYSTEMS.COM28JSI Serial Number: ___________________Silicone Serial Number: _______________Hard-Key Code: _____________________JSI Serial

Pagina 22

WWW.JOHNSONSYSTEMS.COM 29ED = 6 x 15 AMP Duplex EdisonSP = 6 x 20 AMP Stage Pin (Bates) TL = 6 x L5-20R TLG ReceptaclesSO = 19 Pin SocapexTB = Termina

Pagina 23 - WWW.JOHNSONSYSTEMS.COM 23

WWW.JOHNSONSYSTEMS.COM 3IntroductionJ-PACK dimmers are a truly universal hi-performance series of 6 channel dimmer packs. Designed for versatility in

Pagina 24

WWW.JOHNSONSYSTEMS.COM30Troubleshooting ReferenceThis manual is accurate at time of printing and subjectto revisions and technical updates as required

Pagina 25 - WWW.JOHNSONSYSTEMS.COM 25

WWW.JOHNSONSYSTEMS.COM 31Troubleshooting ReferenceThis manual is accurate at time of printing and subjectto revisions and technical updates as require

Pagina 26

www.johnsonsystems.comUser ManualJ-PACK SeriesHi-Power Dimmer PackRev. 1

Pagina 27 - WWW.JOHNSONSYSTEMS.COM 27

WWW.JOHNSONSYSTEMS.COM4Front ViewUser InterfaceRefer to page 14 for detailsCircuit BreakersControl Input XLR ConnectorsRefer to page 13 for detailsCha

Pagina 28

WWW.JOHNSONSYSTEMS.COM 5Left Side ViewRight Side ViewTop ViewAir Intake FanRubber Feet(For RF model only)HandleAir ExhaustVentilationAirExhaustAirInta

Pagina 29 - DP - 120/208 - SP - WM

WWW.JOHNSONSYSTEMS.COM6InstallationJ-Pack Series dimmer packs are intended for indoor use only, in a controlled environment at a room temperature.• M

Pagina 30 - Troubleshooting Reference

WWW.JOHNSONSYSTEMS.COM 7PM = Pipe MountFor pipe mounting, a bracket, C-clamp and safety cable are provided and must be used to secure the dimmer pack

Pagina 31

WWW.JOHNSONSYSTEMS.COM8AC Power SupplyInput TerminalsAC Power Supply Input OptionsJ-PACK Series dimmer packs are capable of various 120VAC power suppl

Pagina 32 - Hi-Power Dimmer Pack

WWW.JOHNSONSYSTEMS.COM 9120 = 120VAC 1Ø 3-Wire via a Single 5' Edison Power CordIncludes a single factory installed 5' (1.5m) Edison power c

Comentarios a estos manuales

Sin comentarios